Servikal Omurga Aksiyel Rotasyon Gonyometre Dizaynı

To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera). With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measurement of "joint position sense" which is recently has rising interest in researches can be made practically with this goniometer.

Cervical Spine Axial Rotation Goniometer Design

-

___

  • Wang SF, Teng CC, Lin KH. Measurement of cervical range of motion pattern during cyclic neck movement by an ultrasound-based motion system. Manual Therapy 2005:10 68-72.
  • Tamara Prushansky, and Zeevi Dvir. Cervical motion testing: methodology and clinical implications. Journal of Manipulative and Physiological Therapeutics 2008:31(7) 503-508
  • Kelvin Jordan. Assessment of Published Reliability Studies for Cervical Spine Range.of.Motion Measurement Tools. Journal of Manipulative and Physiological Therapeutics. 2000:23(3) 180-195
  • Haynes MJ,Edmondston S. Accuracy and reliabılıty of a new, protractor-based neck goniometer. Journal of Manipulative and Physiological Therapeutics. 2002:25 579-86
  • Morphett AL, Colin M. Crawford, Lee D. The use of electromagnetic tracking technology for measurement of passive cervical range of motion: a pilot study. Journal of Manipulative and Physiological Therapeutics. 2003:26152
  • Agarwal S, Allison G, Kevin PS. Reliability of the spin-t cervical goniometer in measuring cervical range of motion in an asymptomatic indian populatıon. Journal of Manipulative and Physiological Therapeutics. 2005:28,487
  • Agarwal S, Allison G, Kevin PS. Validation of the spin-t goniometer, a cervical range of motion device. Journal of Manipulative and Physiological Therapeutics 2005:28, 604-609
  • Williams MA, Christopher JM, Angeliki C, Matthew WC, Simon G. A systematic review of reliability and validity studies of methods for measuring active and passive cervical range of motion. Journal of Manipulative and Physiological Therapeutics. 2010:33,138-155
  • Youdas JW, Carey JR, Garrett TR. Reliability of measurements of cervical spine range of motion-comparison of three methods. Physical Therapy. 1991:71, 98-104
  • Radcliff K, Rubin T, Reitman CA, Smith J, Kepler C, Hilibrand A. Normal cervical alignment. Seminars in spine surgery. 2011: 23, 159-164
  • Lee H, Nicholson LL, Roger D, Sung S. Proprioception and rotation range sensitization associated with subclinical neck pain. Spine. 2005: 30(3), 60-67
  • Revel M, Andre-Deshays C, Minguet M. Cervicocephalic kinesthetic sensibility in patients with cervical pain. Archives of Physical Medicine and Rehabilitation 1991, 72(5):288-291
  • Golomer E, Guillou E, Testa M, Lecoq C, Ohlmann T. Contribution of neck proprioception to subjective vertical perception among experts in physical activities and untrained women. Neuroscience Letters. 2005: 381(1-2) 31-35
Sakarya University Journal of Science-Cover
  • Yayın Aralığı: Yılda 6 Sayı
  • Başlangıç: 1997
  • Yayıncı: Sakarya Üniversitesi
Sayıdaki Diğer Makaleler

Plaklı Bir Damar İle Nıtınol Stent Etkileşimin Sonlu Elemanlar Yöntemiyle İncelenmesi

Recep GÜNEŞ, Ömer ÇAM, M. Kemal APALAK

Tibia Kıkırdağı Üzerindeki Yük Değişimlerine Alt Ekstremite Mekanik Aksın Etkisi: Sonlu Eleman Model Çalışması

Halil Atmaca

Beyin Dalgası Kontrollü Protez Kol Tasarımı

Erol UYAR, Kadir ŞENLİ, Lütfi MUTLU

İnsan Bacak Hareketleri İçin Prototip Dış İskelet Robotik Sisteminin Mekanik Tasarımı Ve Hareket Verilerinin Yapay Sinir Ağları İle Elde Edilmesi

Evren Meltem TOYGAR, Ahmet ÖZKURT, Zeki KIRAL, Mehmet ÇAKMAKÇI, Binnur Gören KIRAL, Yavuz ŞENOL, Taner AKKAN, Yusuf ARMAN, Tolga OLCAY, Necati Mutlu DAĞHAN, Murat KARAGÖZ

Hemşirelik Öğrencilerinde İnternet Bağımlılığının Kişilik Özellikleri Ve Zaman Yönetimi İle İlişkisi

Dilek KÖSE, Nursan ÇINAR, Funda AKDURAN

Radius Kırıklarında Plak Fiksasyonu Ve İntramedüller Çivileme Yöntemlerinin Teorik Olarak İncelenmesi

Halim KOVACI, Hojjat Ghahramanzadeh Asl, İrfan Kaymaz, Akgün ALSARAN, Ayhan ÇELİK, Gürsel SAKA

YÜRÜME YÜKLERİ ALTINDA KEMİK İMPLANT YAPISININ DOĞRU MEKANİK TEMSİLİ

Rıza BAYOĞLU, A. Fethi OKYAR

Hastane Malzemelerinin Sağlık Çalışanlarının Postürüne Etkileri

Erkan ALP, Mehmet BOZKURT, İbrahim BAŞÇİFTÇİ

Silikon İkameli Hidroksiapatitte Biyoaktivite Ve Kemik Oluşumu

Ulvan OZAD, Alan PARİSH, Karin A. HİNG

KARACİĞER DOKUSUNUN SAKLAMA ZAMANINA VE SOLÜSYONUNA BAĞLI MATERYAL ÖZELLİKLERİNİN DEĞİŞİMİ

Mehmet AYYİLDİZ, Berkay YARPUZLU, Cagatay BASDOGAN