Aladdin HW2.0 Optik Düşük Koherens İnterferometre ile Oküler Biyometri ve Pupillometrinin Yeniden Üretilebilirliği

Amaç: Çalışmanın amacı kataraktlı hastalarda ve sağlıklı bireylerde Aladdin HW2.0 (Topcon, Tokyo, Japan) ile oküler biyometri ve pupillometrinin yeniden üretilebilirliğini değerlendirmekti.

Reproducibility of Ocular Biometry and Pupillometry with the Aladdin HW2.0 Optical Low-Coherence Interferometer

Objective: The purpose of the study was to evaluate the reproducibility of ocular biometry and pupillometry with the Aladdin HW2.0 (Topcon, Tokyo, Japan) in patients with cataracts and healthy subjects.

___

  • Turczynowska M, Koźlik-Nowakowska K, Gaca-Wysocka M, Grzybowski A. Effective ocular biometry and intraocular lens power calculation. Eur Ophthalmic Rev. 2016;10(2):94–100. doi:10.17925/EOR.2016.10.02.94
  • Huang J, Savini G, Wu F, et al. Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometer. J Cataract and Refract Surg. 2015;41(10):2233-2241. doi:10.1016/j.jcrs.2015.10.062
  • Savini G, Hoffer KJ, Barboni P, et al. Correction: Accuracy of optical biometry combined with placido disc corneal topography for intraocular lens power calculation. PLoS One. 2017;12(3):e0175145. doi:10.1371/journal.pone.0175145
  • Mandal P, Berrow EJ, Naroo SA, et al. Validity and repeatability of the Aladdin ocular biometer. B J Ophthalmol. 2014;98(2):256-258. doi:10.1136/bjophthalmol-2013-304002
  • Optical biometry & topography system Aladdin series. Available at:http://www.topcon.com.hr/pdf/topcon-aladdin-brochure-EN.pdf. Accessed October 2, 2015.
  • Kaya F, Kocak I, Aydin A, Baybora H, Karabela Y. Comparison of different formulas for intraocular lens power calculation using a new optical biometer. J Fr Ophthalmol. 2015;38(8):717-722. doi:10.1016/j.jfo.2015.03.006
  • Garza-Leon M, Fuentes-de la Fuente HA, García-Treviño AV. Comparison of ocular biometry using the new SC-OCT-based optical biometer and OLCI in patients with clear lens. Vis. Pan-Am. 2016;15(3):75-79.
  • McAlinden C, Gao R, Yu A, et al. Repeatability and agreement of ocular biometry measurements: Aladdin versus Lenstar. B J Ophthalmol. 2017;101(9):1223-1229. doi:10.1136/bjophthalmol-2016-309365
  • Hoffer KJ, Shammas HJ, Savini G, Huang J. Multicenter study of optical low-coherence interferometry and partial-coherence interferometry optical biometers with patients from the United States and China. J Cataract Refract Surg. 2016;42(1):62-67. doi:10.1016/j.jcrs.2015.07.041
  • Sabatino F, Findl O, Maurino V. Comparative analysis of optical biometers. J Cataract Refract Surg. 2016;42(5):685-693. doi:10.1016/j.jcrs.2016.01.051
  • Tang M, Chen A, Li Y, Huang D. Corneal power measurement with Fourier-domain optical coherence tomography. J Cataract Refract Surg. 2010;36(12):2115-2122. doi:10.1016/j.jcrs.2010.07.018
  • Dharwadkar S, Nayak B K. Corneal topography and tomography. J Clin Ophthalmol Res. 2015;3(1):45-62. doi:10.4103/2320-3897.149379
  • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;327(8476):307–310. doi:10.1016/S0140-6736(86)90837-8
  • Currie LA. and Svehla G. Nomenclature for the presentation of results of chemical analysis (IUPAC Recommendations 1994). Pure Appl. Chem. 1994;66:595-608. doi:10.1351/pac199466030595
  • Milka M, Wylegala E, Nowinska A, Janiszewska D, Weglarz B. Comparison of the biometric measurements obtained using IOL Master and ALADDIN systems. Acta Ophthalmol. 2013;91:S252. doi:10.1111/j.1755-3768.2013.4451.x
  • Sorkin N, Rosenblatt A, Barequet IS. Predictability of biometry in patients undergoing cataract surgery. Optom Vis Sci. 2016;93(12):1545-1551. doi:10.1097/OPX.0000000000000990
  • Huang Y, Tang X, Deng J. Comparison of biometric measurements of ALADDIN versus IOL Master 500 in cataract patients. J Clin Ophthalmol. 2015;23:21-23.
  • McAlinden C, Wang Q, Gao R, et al. Axial length measurement failure rates with biometers using swept-source optical coherence tomography compared to partial-coherence interferometry and optical low-coherence interferometry. Am J Ophthalmol. 2017;173:64-69. doi:10.1016/j.ajo.2016.09.019
  • Ortiz A, Galvis V, Tello A, et al. Comparison of three optical biometers: IOLMaster 500, Lenstar LS 900 and Aladdin. Int Ophthalmol. 2019;39(8):1809-1818. doi:10.1007/s10792-018-1006-z
  • Ceran BB, Hashas Karatepe AS, Tasindi E. Can we use anterior segment parameters of an optical biometer and a combined topography system interchangeably? Glo-Kat. 2020;15(1)):38-44. doi:10.37844/glauc.cat.2020.15.8
  • Kanclerz P, Przewłócka K, Wang X. Inter-device measurement variability of vital data parameters for keratorefractive and cataract refractive surgery. Ther Adv Ophthalmol. 2021;13. doi:10.1177/25158414211045750
  • Rosen E. The Pupil and refractive surgery. In: Kohnen T, Koch DD, eds. Cataract and refractive surgery. Essentials in Ophthalmology. Springer, Berlin, Heidelberg. 2005;289-302. doi:10.1007/3-540-26678-X_18
  • Md-Muziman-Syah MM, Suhaimi MA, Sulaiman UH, et al. Mesopic pupillometry in pre-LASIK patients by a Placido-disc topographer and Hartmann-shack aberrometer. Mal J Med Health Sci. 2021;17(2):197-202.
  • Espinosa J, Roig AB, Pérez J, Mas D. A high-resolution binocular video-oculography system: assessment of pupillary light reflex and detection of an early incomplete blink and an upward eye movement. Biomed Eng Online. 2015;14(1):1-12. doi:10.1186/s12938-015-0016-6
  • Kiziltoprak H, Tekin K, Yetkin E, Sekeroglu MA. Static and dynamic pupil characteristics in myopic anisometropic amblyopia. Beyoglu Eye J. 2020;5(2):86-92. doi:10.14744/bej.2020.08760
Online Türk Sağlık Bilimleri Dergisi-Cover
  • ISSN: 2459-1467
  • Yayın Aralığı: Yılda 4 Sayı
  • Başlangıç: 2016
  • Yayıncı: Oğuz KARABAY
Sayıdaki Diğer Makaleler

Enfektif Endokarditli Hastalar: Üçüncü Basamak Tek Merkez Sevk HastanesininBeş Yıllık Deneyimi

Yakup ALSANCAK, Ahmet Seyfeddin GÜRBÜZ, Abdullah İÇLİ, Ahmet Lütfü SERTDEMİR, Hasan KAN, Muhammed Fatih KALELİ, Mustafa DURAN

Kontrolsüz Tip 2 Diabetes Mellitus Tanılı Hastalarda Ortostatik Hipotansiyon ile D Vitamini Eksikliği Arasındaki İlişki

Umut KARABULUT, Dilay KARABULUT, Rıdvan SIVRITEPE, Ece YİĞİT

Radyoaktif İyot Tedavisi Uygulanan Hipertiroidili Hastalarda Kemik Mineral Yoğunluğunun DEXA ile Değerlendirilmesi

Huri Tilla ILCE

Hemşirelik Öğrencilerinin COVID-19 Aşısına İlişkin Görüşleri: Tanımlayıcı, Kesitsel Bir Çalışma

Selmin KÖSE, Müjde ÇALIKUŞU İNCEKAR, Sevim SAVAŞER, Zeynep ERKUT

Kronik Bel Ağrılı Hastalarda Düşük Yoğunluklu Lazer Tedavisinin Etkinliğinin Araştırılması

Zehra ATLI, ELİF YAKŞİ, Mustafa Fatih YAŞAR

Futbolcularda Uygulanan Kuru Kupa Uygulamasının Bazı Performans Parametrelerine Akut Etkisi

Veysel ULUDAĞ, Ayşegül YAPICI ÖKSÜZOĞLU

Böbrek Transplant Hastalarında COVID-19 Hastalığın Uzun Süreli Takip Sonuçları ve COVID-19 İnaktif Aşısının Etkisi Araştırılması

Necattin FIRAT, Savaş SİPAHİ, Aysel TOÇOĞLU, Ahmed Cihad GENÇ, Musa PINAR, Emrah AKIN, Selçuk YAYLACI, Ahmet Bilal GENÇ, Oğuz KARABAY, Hamad DHEIR

Cerrahi Hemşirelerinin Merhamet Yorgunluğu ile Bakım Davranışları Arasındaki İlişkinin Belirlenmesi

Figen DIĞIN, Zeynep KIZILCIK ÖZKAN, Ayşe DÜZGÜN ŞAHİN

İlk Trimester Serum Lipid Profili ile Postterm Gebelik İlişkisi

Selim GÜLÜCÜ, Samettin ÇELIK, Canan Soyer ÇALIŞKAN, Sebahattin ÇELİK

Bilateral Tek Sistem Ektopik Üreter: Erken Tanı ve Başarılı Tedavi

Aytekin KAYMAKÇI, Zekeriya İLÇE, Sevim YENER